    Comparison of the efficacy between Chinese-made and USA-made drug-eluting stents in treatment of ostial lesions of the left anterior descending coronary artery[J]. Chinese Heart Journal, 2010, 22(4): 556-559.
    Citation: Comparison of the efficacy between Chinese-made and USA-made drug-eluting stents in treatment of ostial lesions of the left anterior descending coronary artery[J]. Chinese Heart Journal, 2010, 22(4): 556-559.

    国产与进口药物洗脱支架治疗前降支开口病变的临床疗效比较

    Comparison of the efficacy between Chinese-made and USA-made drug-eluting stents in treatment of ostial lesions of the left anterior descending coronary artery

    • 摘要: 目的: 比较国产与进口药物洗脱支架治疗前降支开口病变的临床疗效。方法: 回顾性分析95例前降支开口病变的患者置入国产支架(国产支架组,n=68)和进口支架(进口支架组,n=27),所有患者均行临床随访,部分患者进行了冠状动脉造影(CAG)复查。结果: 国产支架组的急性心肌梗死患者多于进口支架组,但无统计学差异(46% vs. 33%)。两组的介入成功率均为100%。国产支架组的冠脉钙化率、偏心斑块率和C型病变率均高于进口支架组(分别为20% vs. 4%;14% vs. 0%;28% vs. 7%,均P<0.05)。两组CAG随访的支架内和血管段再狭窄率无统计学差异;两组的主要不良事件发生率也无统计学差异。结论: 国产药物洗脱支架治疗前降支开口病变是安全的,与进口药物洗脱支架具有相似的良好疗效。

       

      Abstract: AIM: To compare the efficacy of Chinese-made and USA-made sirolimus-eluting stents in the treatment of ostial lesion of the left anterior descending (LAD) coronary artery. METHODS: Ninety-five patients with LAD ostial lesion were implanted with stents made in China (Chinese-made stent group, n=68) or stents made in the USA (USA-made stent group, n=27). Follow-ups were conducted in all patients and angiographic examinations were performed in some patients. RESULTS: The procedure was successful in all patients. More acute myocardial infarction was observed in Chinese-made stent group but no significant difference was found between groups (46% vs. 33%, P=0.31). Significantly more calcified, eccentric plaques and C-type lesions were seen in the Chinese-made stent group compared with those seen in the USA-made stent group (20% vs. 4%; 14% vs. 0%; 28% vs. 7%, P<0.05), but angiographic follow-up showed no significant difference in the rate of in-stent and in-segment restenosis between groups. No significance was observed in the rate of main adverse events between groups. CONCLUSION: Compared with USA-made sirolimus-eluting stents, Chinese-made sirolimus-eluting stents are as safe and effective in the treatment of LAD coronary artery ostial lesion.

       

    /